OEM China APEM-5930G Ethernet Sensor for Temperature, Humidity, SO₂ & NO₂ Monitoring - Suppliers & Factory Supplier, Factories

,

Model: APEM-5930G-SO₂-NO₂

,

Introducing the APEM-5930G-SO₂-NO₂, a state-of-the-art monitoring device that seamlessly integrates temperature, humidity, dew point, SO₂, and NO₂ measurements into a single compact unit. This product is designed for precision and quick response, making it ideal for environmental quality assessments and early warning systems in industrial safety. As a leading supplier and factory based in China, we ensure that our devices meet the highest standards for accuracy and reliability, providing you with the data necessary for informed decision-making. Protect your environment and enhance safety with our advanced monitoring solutions.

,

Product Description

Comparison Table

Feature Dimension SO₂-NO₂-5-01
(Low-Range High-Precision Version)
SO₂-NO₂-50-01
(Industrial Wide-Range Version)
Core Positioning Environmental Quality

Precision Areas Early-Warning Monitoring

Industrial Safety

Occupational Health Safety Protection

Range & Precision Low Range (0-5ppm), High Resolution (0.01ppm) Wide Range (0-50ppm), Applicable Resolution (0.1ppm)
Response Speed SO₂: <3s (T90 <80s)
NO₂: <3s (T90 <80s)
SO₂: <3s (T90 <15s)
NO₂: <3s (T90 <30s)
Key Selling Points High Sensitivity, Trend Monitoring, Environmental Compliance Rapid Alarm, Personnel Safety Protection, Industrial Compliance
Typical Users Property Managers, Environmental Agencies, Building Automation System Integrators Plant Safety Managers, Industrial Automation Integrators, EHS Departments

Parameter SO₂-NO₂-5-01

Measurement Content Range Resolution Response Time
SO₂ 0-5ppm 0.01ppm <3s (T90 <80s)
NO₂ 0-5ppm 0.01ppm <3s (T90 <80s)
Temperature -25~80℃ ±0.2℃ (at 25℃) Real-time
Humidity 0~99.9%RH ±2%RH (at 25℃) Real-time
Specifications
Measurement Content SO₂, NO₂, Temperature, Humidity, Dew Point
Power Supply DC12~48V, POE power supply
Communication Protocol Modbus TCP, UDP, SNMP (V1.V2), MQTT
Communication Interface RJ45
Interface 2 channels DI input, 1 channel DO output, 1 channel RS485, 1 channel DC12V output
Alarm Light, sound, email alarm, protocol alerts
Screen Display 3.5 inch TFT color screen
Data Storage 100,000 records
Installation Screw fixation, Magnetic
Dimensions 100*135*35mm

Parameter SO₂-NO₂-50-01

Measurement Content Range Resolution Response Time
SO₂ 0-50ppm 0.1ppm <3s (T90 <15s)
NO₂ 0-50ppm 0.1ppm <3s (T90 <30s)
Temperature -25~80℃ ±0.2℃ (at 25℃) Real-time
Humidity 0~99.9%RH ±2%RH (at 25℃) Real-time
Specifications
Measurement Content SO₂, NO₂, Temperature, Humidity, Dew Point
Power Supply DC12~48V, POE power supply
Communication Protocol Modbus TCP, UDP, SNMP (V1.V2), MQTT
Communication Interface RJ45
Interface 2 channels DI input, 1 channel DO output, 1 channel RS485, 1 channel DC12V output
Alarm Light, sound, email alarm, protocol alerts
Screen Display 3.5 inch TFT color screen
Data Storage 100,000 records
Installation Screw fixation, Magnetic
Dimensions 100*135*35mm

Product Video

Product Dimensions

Product Dimensions Diagram

Product Display

Ethernet All in One Sensor Display 1 Ethernet All in One Sensor Display 2 Ethernet All in One Sensor Display 3 Ethernet All in One Sensor Display 4 Ethernet All in One Sensor Display 5 Ethernet All in One Sensor Display 6 Power over Ethernet Temperature and Humidity Web Sensor Display 7 Power over Ethernet Temperature and Humidity Web Sensor Display 8

Frequently Asked Questions

Q What is the primary difference between the SO₂-NO₂-5-01 and the SO₂-NO₂-50-01 models?

The SO₂-NO₂-5-01 is a high-precision, low-range version (0-5ppm range, 0.01ppm resolution) designed for environmental quality and early-warning monitoring. The SO₂-NO₂-50-01 is an industrial wide-range version (0-50ppm range, 0.1ppm resolution) optimized for industrial safety, EHS compliance, and occupational health protection.

Q What communication protocols and interfaces are supported by these sensors?

Both models feature an RJ45 communication interface and support Modbus TCP, UDP, SNMP (V1/V2), and MQTT protocols, allowing for seamless integration into modern IoT and building automation systems.

Q What power supply options can be used for installation?

The sensors support DC12~48V power input as well as POE (Power over Ethernet) power supply, providing flexible wiring and installation options.

Q How do the sensors alert operators when thresholds are exceeded?

The devices feature multi-channel alarm mechanisms including local light and sound alarms, email notifications, and communication protocol alerts to ensure rapid response times.

Q Do these devices support local data storage?

Yes, both the SO₂-NO₂-5-01 and SO₂-NO₂-50-01 models are equipped with an internal memory capacity capable of storing up to 100,000 records.